{"id":2247,"date":"2020-07-29T18:00:02","date_gmt":"2020-07-29T15:00:02","guid":{"rendered":"http:\/\/turboenergo.ru\/?p=2247"},"modified":"2020-10-26T12:44:00","modified_gmt":"2020-10-26T09:44:00","slug":"vosstanovlennoe-oborudovanie","status":"publish","type":"post","link":"https:\/\/turboenergo.ru\/en\/produktsiya\/vosstanovlennoe-oborudovanie\/","title":{"rendered":"Refurbished equipment"},"content":{"rendered":"<p><\/p>\n<p>&nbsp;<\/p>\n<table style=\"border-collapse: collapse; width: 100%; height: 48px;\">\n<tbody>\n<tr style=\"height: 48px;\">\n<td style=\"width: 100%; height: 48px;\"><strong>This equipment is stored in the Turboenergoremont, LLC warehouse and restored to factory settings.\u00a0\u00a0<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"width: 85.5138%; height: 3073px;\" width=\"1075\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\" width=\"445\"><strong>Product name\u00a0\u00a0 <\/strong><\/td>\n<td style=\"width: 66.5692%; height: 24px;\" colspan=\"2\" width=\"630\"><strong>Characteristics<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\"><strong>Condensing steam turbine:<\/strong><\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Wattage:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">1500 kW.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041a-1.5-1.3<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Rotor speed:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">3000 r\/min.\u00a0\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Steam consumption:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">9,4 Steam tons\/hour.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Inlet steam pressure:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">1,3 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Outlet steam temperature:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">340 \u00b0\u0421.\u00a0\u00a0\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Outlet steam pressure:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">0,008 Mpa.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 49px;\"><strong>Back pressure steam turbine:<\/strong><\/td>\n<td style=\"width: 38.8476%; height: 49px;\">Wattage:<\/td>\n<td style=\"width: 27.7216%; height: 49px;\">250 \u2013 12000 kW.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0420-0,25-1,3\/0,5<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Rotor speed:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">3000 r\/min.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0420-2,5-21\/3<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">&#8211; Turbine:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u0420-2,5-35\/5<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Steam pressure before the turbine stop valve:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">1,3 \u2013 3,4 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u0420-4-35\/5<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Steam temperature before the turbine stop valve:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">192 \u2013 470\u00b0\u0421<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0420-4-35\/15\u041c<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Turbine temperature pressure:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">0,5 \u2013 1,4 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0420-4-35\/5\u041c-1<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Steam consumption:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">11 \u2013 125 ton\/hour.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u0420-6-35\/3<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Asynchronous\/synchronous generator<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u0420-6-35\/5<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Generator voltage:<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">6300\/10500 (-5%+10%) V.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0420-6-35\/5\u041c<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Generator cooling type:\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">Air.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0420-6-3,4\/0,5-1<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0420-12-35\/5<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0420-12-35\/5\u041c<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\"><strong>Heating steam turbine:<\/strong><\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Maximum continuous rating:\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">25, 30, 50, 110, 120\u00a0 MW.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0422-25-90<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Rotor speed:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">3000 r\/min.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0422-30-90<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Steam initial parameters:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0422- 50-90\u041c<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Pressure:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">8,8-12,8 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0422-110\/120-130-4<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u0422emperature:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">470 -530 \u00b0\u0421.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u0422-120-12,8<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Rated live steam consumption:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">160 \u2013 260 ton\/hour.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">\u041caximum performance of heat extraction:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">290- 360 GJ\/hour<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Pressure control range in the heat extraction:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">0,07\u20130,25 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Asynchronous\/synchronous generator<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Generator voltage:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">6300\/10500 (-5%+10%) V.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Generator cooling type:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">Air\/hydrogen<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\"><strong>Backpressure and extraction turbine:<\/strong><\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Maximum continuous rating:<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">6000 \u2013 12000 kW.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f\u0420-6-3,4\/0,5\/0,1-1<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Rotor speed:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">3000 r\/min.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f\u0420-6-35\/15\/5<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Total pressure:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">3,4 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f\u0420-6-35\/10\/5\u041c<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u0422emperature:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">420-445 \u00b0\u0421.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f\u0420-12-3,4-3,4\/1.0\/0.1<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Steam consumption:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">40 \u2013 105 Ton\/hour.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Extraction pressure:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">0,4 \u2013 1,75 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Turbine temperature pressure:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">0,07-0,7 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Asynchronous\/synchronous generator<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Generator voltage:<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">6300\/10500 (-5%+10%) V.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Generator cooling type:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">Air<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\"><strong>Extraction turbine:<\/strong><\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Maximum continuous rating.<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">6000 (6600) kW.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f-6-3,4\/1,0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Rotor speed \u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">3000 r\/min.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u041f-6 35\/5\u041c<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">live steam parameters (performance range)<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u00a0Total pressure:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">3,4. MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Temperature:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">435 \u00b0\u0421.\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Total turbine pressure:<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">with extraction on:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">3,5 -6,08 KPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">in condensing mode:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">5 KPa.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Regulated production extraction<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">performance range:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">total pressure:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">0,8-1,3 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Temperature:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">208-333 \u00b0\u0421.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Consumption rate:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">0-48 Ton\/hour.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Rated steam consumption on one turbine:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">43-53 Ton\/hour.\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Condenser type:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u041aP-540\/2\u00a0\u00a0\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Asynchronous\/synchronous generator<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Generator voltage:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">6300\/10500 (-5%+10%) V.\u00a0\u00a0\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Generator cooling type:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">Air.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\"><strong>Unit extraction turbine<\/strong><\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Wattage:<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">1,5 \u2013 3,0 MW.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f-1,5\/6,3-4,0\/0,5<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Rotor speed:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">7500 r\/min.\u00a0\u00a0\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f-2,0\/6,3-2,4\/0.5<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Steam pressure before turbine:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">2,4-4,0 MPa<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f-3,0\/10,5-4,0\/0,9<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Steam temperature:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">350-435 \u00b0\u0421.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Steam consumption on one turbine:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">12- 25 Ton\/hour.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Extraction steam pressure:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">0,5-0,9 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Turbine steam pressure:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">8,0-8,8 KPa.\u00a0\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Asynchronous\/synchronous generator<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Generator voltage:<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">6300\/10500 (-5%+10%) V.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Generator cooling type:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">Air<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\"><strong>Extraction heating steam turbine:<\/strong><\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Wattage:<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">12 &#8211; 35 MW.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f\u0422-12-35\/10\u041c<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Rotor speed:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">3000 r\/min.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f\u0422-23,6\/29-2,9\/1,3<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">live steam<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f\u0422-25\/30-90\/10\u041c<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Pressure:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">3,4 &#8211; 8,8 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f\u0422-35-8,8<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Temperature:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">470 \u2013 535 \u00b0\u0421.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u041f\u0422-35-8,8<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Consumption:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">119 \u2013 240 \u0442\/\u0447.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Pressure variation limits in the regulated steam extraction<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Production:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">0,78-1,27 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Heating:\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">0,069-0,245 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Asynchronous\/synchronous generator<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 41.7286%; height: 48px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 48px;\">Generator voltage:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">6300\/10500 (-5%+10%) V.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Generator cooling type:\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">Air.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 41.7286%; height: 312px;\" rowspan=\"10\">\u041e\u0420-1,5-3<\/td>\n<td style=\"width: 38.8476%; height: 24px;\">Wattage:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">1,5 MW.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 38.8476%; height: 24px;\">Rotor speed:\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">3000 r\/min.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 38.8476%; height: 24px;\">live steam parameters<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 38.8476%; height: 24px;\">Total pressure:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">1,5 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 38.8476%; height: 24px;\">Temperature:\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">350 \u00b0\u0421.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 38.8476%; height: 48px;\">Total turbine steam pressure:<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">0,3 MPa.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 38.8476%; height: 24px;\">Weight with foundation frame:<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">19300 kg.<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 38.8476%; height: 48px;\">Asynchronous\/synchronous generator<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">\u00a0<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"width: 38.8476%; height: 48px;\">Generator voltage:<\/td>\n<td style=\"width: 27.7216%; height: 48px;\">6300\/10500 (-5%+10%) V.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 38.8476%; height: 24px;\">Generator cooling type:\u00a0\u00a0\u00a0<\/td>\n<td style=\"width: 27.7216%; height: 24px;\">Air.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>","protected":false},"excerpt":{"rendered":"&nbsp; This equipment is stored in the Turboenergoremont, LLC warehouse and restored to factory settings.\u00a0\u00a0 Product name\u00a0\u00a0 Characteristics Condensing steam turbine: Wattage: 1500 kW. \u041a-1.5-1.3 Rotor speed: 3000 r\/min.\u00a0\u00a0 \u00a0 Steam consumption: 9,4 Steam tons\/hour. \u00a0 Inlet steam pressure:\u00a0\u00a0 1,3 MPa. \u00a0 Outlet steam temperature:\u00a0\u00a0\u00a0 340 \u00b0\u0421.\u00a0\u00a0\u00a0 \u00a0 Outlet steam pressure:\u00a0\u00a0 0,008 Mpa. Back pressure&hellip;","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[59],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.7.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Refurbished equipment - Turboenergoremont<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Refurbished equipment - Turboenergoremont\" \/>\n<meta property=\"og:description\" content=\"&nbsp; This equipment is stored in the Turboenergoremont, LLC warehouse and restored to factory settings.\u00a0\u00a0 Product name\u00a0\u00a0 Characteristics Condensing steam turbine: Wattage: 1500 kW. \u041a-1.5-1.3 Rotor speed: 3000 r\/min.\u00a0\u00a0 \u00a0 Steam consumption: 9,4 Steam tons\/hour. \u00a0 Inlet steam pressure:\u00a0\u00a0 1,3 MPa. \u00a0 Outlet steam temperature:\u00a0\u00a0\u00a0 340 \u00b0\u0421.\u00a0\u00a0\u00a0 \u00a0 Outlet steam pressure:\u00a0\u00a0 0,008 Mpa. Back pressure&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/\" \/>\n<meta property=\"og:site_name\" content=\"Turboenergoremont\" \/>\n<meta property=\"article:published_time\" content=\"2020-07-29T15:00:02+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-10-26T09:44:00+00:00\" \/>\n<meta name=\"author\" content=\"\u0412\u043b\u0430\u0434\u0438\u043c\u0438\u0440 \u0410\u043b\u0435\u043a\u0441\u0430\u043d\u0434\u0440\u043e\u0432\u0438\u0447\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"\u0412\u043b\u0430\u0434\u0438\u043c\u0438\u0440 \u0410\u043b\u0435\u043a\u0441\u0430\u043d\u0434\u0440\u043e\u0432\u0438\u0447\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/\",\"url\":\"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/\",\"name\":\"Refurbished equipment - Turboenergoremont\",\"isPartOf\":{\"@id\":\"https:\/\/turboenergo.ru\/#website\"},\"datePublished\":\"2020-07-29T15:00:02+00:00\",\"dateModified\":\"2020-10-26T09:44:00+00:00\",\"author\":{\"@id\":\"https:\/\/turboenergo.ru\/#\/schema\/person\/1fac9124b262d08d5d9f1fcac288cc77\"},\"breadcrumb\":{\"@id\":\"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u0413\u043b\u0430\u0432\u043d\u0430\u044f \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0430\",\"item\":\"https:\/\/turboenergo.ru\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u0412\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/turboenergo.ru\/#website\",\"url\":\"https:\/\/turboenergo.ru\/\",\"name\":\"Turboenergoremont\",\"description\":\"Clean energy\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/turboenergo.ru\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/turboenergo.ru\/#\/schema\/person\/1fac9124b262d08d5d9f1fcac288cc77\",\"name\":\"\u0412\u043b\u0430\u0434\u0438\u043c\u0438\u0440 \u0410\u043b\u0435\u043a\u0441\u0430\u043d\u0434\u0440\u043e\u0432\u0438\u0447\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Refurbished equipment - Turboenergoremont","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/","og_locale":"en_US","og_type":"article","og_title":"Refurbished equipment - Turboenergoremont","og_description":"&nbsp; This equipment is stored in the Turboenergoremont, LLC warehouse and restored to factory settings.\u00a0\u00a0 Product name\u00a0\u00a0 Characteristics Condensing steam turbine: Wattage: 1500 kW. \u041a-1.5-1.3 Rotor speed: 3000 r\/min.\u00a0\u00a0 \u00a0 Steam consumption: 9,4 Steam tons\/hour. \u00a0 Inlet steam pressure:\u00a0\u00a0 1,3 MPa. \u00a0 Outlet steam temperature:\u00a0\u00a0\u00a0 340 \u00b0\u0421.\u00a0\u00a0\u00a0 \u00a0 Outlet steam pressure:\u00a0\u00a0 0,008 Mpa. Back pressure&hellip;","og_url":"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/","og_site_name":"Turboenergoremont","article_published_time":"2020-07-29T15:00:02+00:00","article_modified_time":"2020-10-26T09:44:00+00:00","author":"\u0412\u043b\u0430\u0434\u0438\u043c\u0438\u0440 \u0410\u043b\u0435\u043a\u0441\u0430\u043d\u0434\u0440\u043e\u0432\u0438\u0447","twitter_card":"summary_large_image","twitter_misc":{"Written by":"\u0412\u043b\u0430\u0434\u0438\u043c\u0438\u0440 \u0410\u043b\u0435\u043a\u0441\u0430\u043d\u0434\u0440\u043e\u0432\u0438\u0447","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/","url":"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/","name":"Refurbished equipment - Turboenergoremont","isPartOf":{"@id":"https:\/\/turboenergo.ru\/#website"},"datePublished":"2020-07-29T15:00:02+00:00","dateModified":"2020-10-26T09:44:00+00:00","author":{"@id":"https:\/\/turboenergo.ru\/#\/schema\/person\/1fac9124b262d08d5d9f1fcac288cc77"},"breadcrumb":{"@id":"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/turboenergo.ru\/produktsiya\/vosstanovlennoe-oborudovanie\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u0413\u043b\u0430\u0432\u043d\u0430\u044f \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0430","item":"https:\/\/turboenergo.ru\/"},{"@type":"ListItem","position":2,"name":"\u0412\u043e\u0441\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435"}]},{"@type":"WebSite","@id":"https:\/\/turboenergo.ru\/#website","url":"https:\/\/turboenergo.ru\/","name":"Turboenergoremont","description":"Clean energy","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/turboenergo.ru\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/turboenergo.ru\/#\/schema\/person\/1fac9124b262d08d5d9f1fcac288cc77","name":"\u0412\u043b\u0430\u0434\u0438\u043c\u0438\u0440 \u0410\u043b\u0435\u043a\u0441\u0430\u043d\u0434\u0440\u043e\u0432\u0438\u0447"}]}},"_links":{"self":[{"href":"https:\/\/turboenergo.ru\/en\/wp-json\/wp\/v2\/posts\/2247"}],"collection":[{"href":"https:\/\/turboenergo.ru\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/turboenergo.ru\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/turboenergo.ru\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/turboenergo.ru\/en\/wp-json\/wp\/v2\/comments?post=2247"}],"version-history":[{"count":33,"href":"https:\/\/turboenergo.ru\/en\/wp-json\/wp\/v2\/posts\/2247\/revisions"}],"predecessor-version":[{"id":2911,"href":"https:\/\/turboenergo.ru\/en\/wp-json\/wp\/v2\/posts\/2247\/revisions\/2911"}],"wp:attachment":[{"href":"https:\/\/turboenergo.ru\/en\/wp-json\/wp\/v2\/media?parent=2247"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/turboenergo.ru\/en\/wp-json\/wp\/v2\/categories?post=2247"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/turboenergo.ru\/en\/wp-json\/wp\/v2\/tags?post=2247"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}